Product · Permeation Calibration

Perm-Calibrator System

Advanced permeation-based calibration system for ultra-low concentration gas standards—delivering NIST-traceable precision from ng/L to μg/L ranges with exceptional stability.

ng/L - μg/L Concentration Range
±2% Accuracy
NIST Traceable
< 30 min Warm-up Time

Precision Permeation Technology

NIST-traceable calibration source providing unmatched accuracy for validating analytical instruments operating at trace concentration levels.

Ultra-Precise Gas Standards

The Perm-Calibrator™ system generates ultra-precise gas standards through controlled permeation technology. This NIST-traceable calibration source provides unmatched accuracy for validating analytical instruments operating at trace concentration levels.

Utilizing temperature-controlled permeation tubes and precision mass flow control, the system delivers stable, reproducible concentrations from ng/L to μg/L ranges with exceptional long-term stability.

Advanced Features

  • NIST-traceable permeation tubes
  • Temperature-controlled oven (±0.1°C)
  • Precision dilution gas control
  • Real-time concentration monitoring
  • Automated calibration sequences
  • Data logging and documentation

Key Benefits

Ultra-low detection limits
Long-term stability >1 year
Multiple compound capability
Automated operation
Regulatory compliance
Easy integration

Technical Specifications

Comprehensive performance specifications for precision permeation-based calibration systems.

Parameter Specification Notes
Concentration Range 10 ng/L to 10 mg/L Depending on permeation tube
Accuracy ±2% of reading NIST-traceable
Reproducibility ±1% RSD Short-term (1 hour)
Temperature Control ±0.1°C stability 40°C to 130°C range
Flow Rate Range 0.1 to 5000 mL/min Mass flow controlled
Warm-up Time < 30 minutes To specified accuracy
Power Requirements 100-240V AC, 50-60Hz 500W maximum
Dimensions 48 x 43 x 30 cm Benchtop configuration

Available Permeation Compounds

Comprehensive library of NIST-traceable permeation tubes for diverse analytical applications across multiple industries.

🧪 VOCs & Solvents

  • Benzene
  • Toluene
  • Xylenes
  • Acetone
  • Methanol
  • Ethanol
  • Dichloromethane
  • Chloroform
  • Carbon Tetrachloride
  • Perchloroethylene

🌍 Environmental Compounds

  • Hydrogen Sulfide
  • Sulfur Dioxide
  • Ammonia
  • Nitrogen Dioxide
  • Formaldehyde
  • Mercury
  • Phenol
  • Naphthalene
  • Styrene
  • Vinyl Chloride

⚠️ Industrial Hazards

  • Ethylene Oxide
  • Hydrazine
  • Phosgene
  • TCP/DCP
  • DMDS
  • Acrolein
  • Acrylonitrile
  • 1,3-Butadiene
  • Epichlorohydrin
  • Methyl Isocyanate

System Configurations

Scalable configurations from single-tube systems to integrated automated solutions for comprehensive calibration requirements.

🔬 Single Tube System

  • One permeation tube chamber
  • Manual tube exchange
  • Ideal for single compound work
  • Cost-effective solution
  • Compact benchtop design

Starting at €15,000

🎠 Multi-Tube Carousel

  • Up to 8 permeation tubes
  • Automated tube selection
  • Multiple compound capability
  • Sequence programming
  • Enhanced productivity

Starting at €28,000

⚙️ Integrated System

  • Built-in analyzer interface
  • Automated calibration cycles
  • Data management system
  • 21 CFR Part 11 compliance
  • Turnkey solution

Custom Quote

Applications & Industries

Comprehensive calibration solutions across analytical laboratories, manufacturing, and research institutions requiring ultra-precise gas standards.

Primary Applications

  • Instrument Calibration - PID, FID, IMS, GC-MS systems
  • Method Validation - EPA, OSHA, NIOSH compliance
  • Quality Assurance - Laboratory accreditation requirements
  • Research & Development - Sensor testing and validation
  • Field Instrument Verification - Portable analyzer checks
  • Training & Education - Hands-on calibration experience

Target Industries

  • Environmental Laboratories - Water, soil, air analysis
  • Chemical Manufacturing - Process monitoring
  • Pharmaceutical - Residual solvent analysis
  • Semiconductor - Cleanroom contamination
  • Petrochemical - Refinery safety monitoring
  • Research Institutions - Academic and government labs

Quality Assurance & Compliance

Complete certification and support services ensuring regulatory compliance and measurement traceability.

📋 Certifications

  • NIST-traceable permeation rates
  • Procedures meeting ISO 17025 requirements
  • CE marking (European safety)
  • FCC Part 15 (electromagnetic)
  • RoHS compliance

📄 Documentation

  • Calibration certificates
  • Operating procedures (SOPs)
  • Maintenance schedules
  • Uncertainty calculations
  • Traceability records

🛠️ Support Services

  • Annual calibration service
  • Technical support hotline
  • Remote diagnostics
  • Training programs
  • Custom tube development

Ready to Enhance Your Calibration Standards?

Contact our calibration experts to discuss your specific requirements and configure the optimal Perm-Calibrator system for your laboratory.

ng/L to μg/L range · ±2% accuracy · NIST traceable · Multi-compound capability